Heidelberg Materials - Matera
Emissioni Forno
Analisi Valori Medi
| Polveri | ||
| Ossidi di zolfo [SO2] | ||
| Ossidi di azoto [NOx come NO2] | ||
| Ossido di carbonio [CO] | ||
| Acido cloridrico [HCl] | ||
| Carbonio Organico totale [TOC] | ||
| Ammoniaca [NH3] |
[Mese Precedente] [Mese Successivo] [Anno 2024] [Principale]
| |
Polveri @ 10%O2 - convalidato mg/Nm³ |
SO2 @ 10%O2 - convalidato mg/Nm³ |
NOx @ 10%O2 - convalidato mg/Nm³ |
CO @ 10%O2 - convalidato mg/Nm³ |
HCl @ 10%O2 - convalidato mg/Nm³ |
TOC @ 10%O2 - convalidato mg/Nm³ |
NH3 @ 10%O2 - convalidato mg/Nm³ |
| 01/10/2024 | 1.8 | 3.8 | 396.2 | 430.6 | 0.3 | 17.3 | 3.2 |
| 02/10/2024 | 1.6 | 3.7 | 377.2 | 363.9 | 0.3 | 13.1 | 3.5 |
| 03/10/2024 | 1.5 | 3.7 | 399.3 | 529.8 | 0.4 | 10.4 | 4.5 |
| 04/10/2024 | 1.5 | 3.7 | 399.9 | 472.4 | 1.0 | 8.7 | 6.3 |
| 05/10/2024 | 1.5 | 3.8 | 398.1 | 408.7 | 0.6 | 9.3 | 4.1 |
| 06/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 07/10/2024 | 0.0 * | 0.0 * | 0.0 * | 0.0 * | 0.0 * | 0.0 * | 0.0 * |
| 08/10/2024 | 1.7 | 3.7 | 398.2 | 519.5 | 0.3 | 15.3 | 3.2 |
| 09/10/2024 | 2.0 | 6.8 | 398.6 | 464.0 | 0.8 | 19.6 | 4.7 |
| 10/10/2024 | 1.8 | 6.2 | 402.6 | 525.4 | 0.7 | 18.9 | 10.0 |
| 11/10/2024 | 1.9 | 4.7 | 397.7 | 340.5 | 0.3 | 15.9 | 3.9 |
| 12/10/2024 | 2.0 | 3.9 | 381.0 | 252.2 | 0.3 | 13.8 | 3.6 |
| 13/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 14/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 15/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 16/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 17/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 18/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 19/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 20/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 21/10/2024 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 22/10/2024 | 0.1 * | 3.7 * | 386.4 * | 353.2 * | 0.4 * | 11.8 * | 3.2 * |
| 23/10/2024 | 0.1 | 5.9 | 393.9 | 484.2 | 1.1 | 15.5 | 6.5 |
| 24/10/2024 | 0.1 | 3.7 | 395.1 | 417.7 | 0.4 | 18.4 | 3.2 |
| 25/10/2024 | 0.1 | 5.9 | 400.4 | 487.3 | 0.9 | 17.9 | 4.1 |
| 26/10/2024 | 0.1 | 5.8 | 400.3 | 401.5 | 1.2 | 23.2 | 5.3 |
| 27/10/2024 | 0.1 | 3.7 | 389.6 | 434.4 | 0.3 | 15.8 | 3.7 |
| 28/10/2024 | 0.1 | 6.7 | 383.7 | 513.5 | 0.8 | 17.5 | 5.1 |
| 29/10/2024 | 0.2 | 12.1 | 396.7 | 523.4 | 1.0 | 17.1 | 5.4 |
| 30/10/2024 | 0.2 | 14.8 | 397.0 | 531.2 | 1.0 | 16.6 | 7.2 |
| 31/10/2024 | 0.1 | 10.1 | 400.3 | 542.8 | 0.5 | 21.0 | 5.8 |
| Soglia | 10.0 | 50.0 | 450.0 | 600.0 | 10.0 | 30.0 | 30.0 |
| Nr Sup. | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Max | 2.0 | 14.8 | 402.6 | 542.8 | 1.2 | 23.2 | 10.0 |
| Min | 0.1 | 3.7 | 377.2 | 252.2 | 0.3 | 8.7 | 3.2 |
| |
Polveri @ 10%O2 - convalidato mg/Nm³ |
SO2 @ 10%O2 - convalidato mg/Nm³ |
NOx @ 10%O2 - convalidato mg/Nm³ |
CO @ 10%O2 - convalidato mg/Nm³ |
HCl @ 10%O2 - convalidato mg/Nm³ |
TOC @ 10%O2 - convalidato mg/Nm³ |
NH3 @ 10%O2 - convalidato mg/Nm³ |
| Mese | 0.9 | 5.9 | 394.9 | 456.2 | 0.6 | 16.1 | 4.9 |
| SemiOre valide | 862 | 862 | 862 | 862 | 862 | 862 | 862 |
| SemiOre N.F. | 934 | 934 | 934 | 934 | 934 | 934 | 934 |
[Mese Precedente] [Mese Successivo] [Anno 2024] [Principale]
| Non Valido - Le misurazioni non sono significative in quanto durante il periodo le apparecchiature od il sistema di misurazione ha dichiarato malfunzionamenti, quindi le misurazioni effettuate non sono attendibili. - Lo stato dell'impianto controllato è relativo a momenti di esercizio transitorio (avviamento o fermata). | |
| Non Applicabile Durante la giornata l'impianto controllato ha superato lo stato di minimo tecnico per una durata inferiore alla mimima richiesta, quindi il valore medio calcolato non è significativo (ex DM 21/12/1995). L'impianto controllato, per quanto concerna la media aggregata, è da considerare fermo | |
| Non Disponibile Le informazioni per la grandezza non sono disponibili a causa di problemi tecnici del sistema di misurazione o memorizzazione. | |
| Fuori Scansione Le informazioni non sono state effettuate a causa di guasto o manutenzione delle apparecchiature di misurazione. | |
| Superamento soglia normativa Il valore medio misurato è superiore al valore massimo ammissibile. |
PF Sistemi s.r.l. Milano