Italcementi - Matera 
Emissioni Forno 
Analisi Valori Medi 

LIMITI DI EMISSIONE (dal 01/01/2018)

Polveri
10
[mg/Nm3]
Ossidi di zolfo [SO2]
50
[mg/Nm3]
Ossidi di azoto [NOx come NO2]
450
[mg/Nm3]
Ossido di carbonio [CO]
600
[mg/Nm3]
Acido cloridrico [HCl]
10
[mg/Nm3]
Carbonio Organico totale [TOC]
30
[mg/Nm3 come C]
Ammoniaca [NH3]
30
[mg/Nm3]

  [Mese Precedente]    [Mese Successivo]    [Anno 2019]    [Principale]

 

Mensile lineare 01/2019
 
 
Polveri @ 10%O2 
- convalidato 
 
mg/Nm³
 
SO2 @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NOx @ 10%O2 - 
convalidato 
 
mg/Nm³
 
CO @ 10%O2 - convalidato 
 
 
mg/Nm³
 
HCl @ 10%O2 - 
convalidato 
 
mg/Nm³
 
TOC @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NH3 @ 10%O2 - 
convalidato 
 
mg/Nm³
01/01/2019 0.5 24.1 349.6 296.1 0.6 20.8 4.2
02/01/2019 0.6 16.7 349.4 378.7 1.0 20.8 4.2
03/01/2019 0.6 * 16.4 * 223.2 * 372.5 * 1.0 * 18.1 * 4.2 *
04/01/2019 0.8 25.6 373.3 473.1 0.6 22.4 4.2
05/01/2019 0.0 * 0.0 * 0.0 * 0.0 * 0.0 * 0.0 * 0.0 *
06/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
07/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
08/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
09/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
10/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
11/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
12/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
13/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
14/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
15/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
16/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
17/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
18/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
19/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
20/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
21/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
22/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
23/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
24/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
25/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
26/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
27/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
28/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
29/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
30/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
31/01/2019    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
  
Soglia 10.0 50.0 450.0 600.0 10.0 30.0 30.0
Nr Sup. 0 0 0 0 0 0 0
Max 0.8 25.6 373.3 473.1 1.0 22.4 4.2
Min 0.5 16.7 349.4 296.1 0.6 20.8 4.2
  
 
  
 
Polveri @ 10%O2 
- convalidato 
 
mg/Nm³
 
SO2 @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NOx @ 10%O2 - 
convalidato 
 
mg/Nm³
 
CO @ 10%O2 - convalidato 
 
 
mg/Nm³
 
HCl @ 10%O2 - 
convalidato 
 
mg/Nm³
 
TOC @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NH3 @ 10%O2 - 
convalidato 
 
mg/Nm³
Mese    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
SemiOre valide 113 113 113 113 113 113 113
SemiOre N.F. 192 192 192 192 192 192 192
  

  [Mese Precedente]    [Mese Successivo]    [Anno 2019]    [Principale]


Legenda MESE

*
Non Valido
- Le misurazioni non sono significative in quanto durante il periodo le apparecchiature od il sistema di misurazione ha dichiarato malfunzionamenti, quindi le misurazioni effettuate non sono attendibili.
- Lo stato dell'impianto controllato è relativo a momenti di esercizio transitorio (avviamento o fermata).
N.A.
Non Applicabile
Durante la giornata l'impianto controllato ha superato lo stato di minimo tecnico per una durata inferiore alla mimima richiesta, quindi il valore medio calcolato non è significativo (ex D.Lgs. 152/06). L'impianto controllato, per quanto concerna la media aggregata, è da considerare fermo
N.D.
Non Disponibile
Le informazioni per la grandezza non sono disponibili a causa di problemi tecnici del sistema di misurazione o memorizzazione.
F.S.
Fuori Scansione
Le informazioni non sono state effettuate a causa di guasto o manutenzione delle apparecchiature di misurazione.
>
Superamento soglia normativa
Il valore medio misurato è superiore al valore massimo ammissibile.

 

 

Italcementi - Matera - 752-0100-00 

PF Sistemi s.r.l. Milano