Italcementi - Matera
Emissioni Forno
Analisi Valori Medi
| Polveri | ||
| Ossidi di zolfo [SO2] | ||
| Ossidi di azoto [NOx come NO2] | ||
| Ossido di carbonio [CO] | ||
| Acido cloridrico [HCl] | ||
| Carbonio Organico totale [TOC] | ||
| Ammoniaca [NH3] |
[Mese Precedente] [Mese Successivo] [Anno 2020] [Principale]
| |
Polveri @ 10%O2 - convalidato mg/Nm³ |
SO2 @ 10%O2 - convalidato mg/Nm³ |
NOx @ 10%O2 - convalidato mg/Nm³ |
CO @ 10%O2 - convalidato mg/Nm³ |
HCl @ 10%O2 - convalidato mg/Nm³ |
TOC @ 10%O2 - convalidato mg/Nm³ |
NH3 @ 10%O2 - convalidato mg/Nm³ |
| 01/07/2020 | 3.1 | 3.6 | 397.9 | 339.9 | 0.6 | 13.5 | 4.2 |
| 02/07/2020 | 3.4 | 3.6 | 396.9 | 452.2 | 0.6 | 12.4 | 4.2 |
| 03/07/2020 | 2.7 | 3.6 | 358.5 | 401.6 | 0.6 | 11.3 | 4.2 |
| 04/07/2020 | 3.0 | 3.6 | 375.5 | 460.4 | 0.6 | 14.0 | 4.2 |
| 05/07/2020 | 3.3 | 3.6 | 386.9 | 428.2 | 0.6 | 16.0 | 4.2 |
| 06/07/2020 | 3.4 | 4.7 | 362.5 | 458.6 | 0.6 | 18.3 | 7.2 |
| 07/07/2020 | 4.0 | 4.1 | 349.1 | 466.0 | 0.6 | 10.7 | 6.8 |
| 08/07/2020 | 4.8 * | 3.7 * | 379.7 * | 463.3 * | 0.6 * | 10.2 * | 7.3 * |
| 09/07/2020 | 6.0 | 3.6 | 388.6 | 493.3 | 0.6 | 15.9 | 5.4 |
| 10/07/2020 | 4.4 | 3.6 | 366.8 | 498.4 | 0.6 | 14.0 | 4.2 |
| 11/07/2020 | 4.6 * | 3.6 * | 392.4 * | 351.0 * | 0.6 * | 14.7 * | 4.2 * |
| 12/07/2020 | 2.9 | 3.6 | 393.1 | 281.3 | 0.6 | 16.2 | 4.2 |
| 13/07/2020 | 3.7 | 4.4 | 384.0 | 442.3 | 1.1 | 18.4 | 4.8 |
| 14/07/2020 | 3.9 | 3.7 | 392.5 | 408.3 | 0.6 | 18.1 | 4.8 |
| 15/07/2020 | 4.8 | 6.2 | 377.7 | 491.4 | 0.6 | 20.9 | 10.2 |
| 16/07/2020 | 5.1 | 4.0 | 280.7 | 397.2 | 0.6 | 19.1 | 7.6 |
| 17/07/2020 | 4.6 | 3.6 | 393.6 | 423.7 | 0.6 | 15.7 | 4.2 |
| 18/07/2020 | 4.8 | 3.6 | 369.2 | 479.2 | 0.6 | 14.4 | 4.2 |
| 19/07/2020 | 4.0 | 3.6 | 400.2 | 457.9 | 0.6 | 16.7 | 4.8 |
| 20/07/2020 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 21/07/2020 | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. | N.A. |
| 22/07/2020 | 1.5 * | 3.6 * | 393.2 * | 337.5 * | 5.4 * | 12.0 * | 4.2 * |
| 23/07/2020 | 2.5 | 4.3 | 397.0 | 469.8 | 2.7 | 13.1 | 5.9 |
| 24/07/2020 | 3.1 | 3.6 | 381.5 | 416.1 | 0.8 | 12.8 | 4.4 |
| 25/07/2020 | 3.1 * | 3.9 * | 352.7 * | 389.2 * | 0.6 * | 12.9 * | 6.4 * |
| 26/07/2020 | 3.0 | 3.6 | 396.4 | 468.6 | 0.6 | 13.0 | 4.2 |
| 27/07/2020 | 3.5 | 3.6 | 395.8 | 472.7 | 0.6 | 14.7 | 4.2 |
| 28/07/2020 | 4.0 | 3.7 | 392.4 | 432.0 | 0.6 | 14.5 | 5.5 |
| 29/07/2020 | 3.9 | 5.4 | 404.6 | 436.4 | 0.7 | 17.4 | 6.5 |
| 30/07/2020 | 4.7 | 3.9 | 395.4 | 398.7 | 0.6 | 19.3 | 4.2 |
| 31/07/2020 | 3.3 | 12.7 | 391.0 | 305.5 | 3.7 | 14.7 | 8.1 |
| Soglia | 10.0 | 50.0 | 450.0 | 600.0 | 10.0 | 30.0 | 30.0 |
| Nr Sup. | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Max | 6.0 | 12.7 | 404.6 | 498.4 | 3.7 | 20.9 | 10.2 |
| Min | 2.5 | 3.6 | 280.7 | 281.3 | 0.6 | 10.7 | 4.2 |
| |
Polveri @ 10%O2 - convalidato mg/Nm³ |
SO2 @ 10%O2 - convalidato mg/Nm³ |
NOx @ 10%O2 - convalidato mg/Nm³ |
CO @ 10%O2 - convalidato mg/Nm³ |
HCl @ 10%O2 - convalidato mg/Nm³ |
TOC @ 10%O2 - convalidato mg/Nm³ |
NH3 @ 10%O2 - convalidato mg/Nm³ |
| Mese | 3.8 | 4.1 | 380.8 | 429.7 | 0.8 | 15.1 | 5.3 |
| SemiOre valide | 1161 | 1162 | 1162 | 1162 | 1162 | 1162 | 1162 |
| SemiOre N.F. | 1283 | 1283 | 1283 | 1283 | 1283 | 1283 | 1283 |
[Mese Precedente] [Mese Successivo] [Anno 2020] [Principale]
| Non Valido - Le misurazioni non sono significative in quanto durante il periodo le apparecchiature od il sistema di misurazione ha dichiarato malfunzionamenti, quindi le misurazioni effettuate non sono attendibili. - Lo stato dell'impianto controllato è relativo a momenti di esercizio transitorio (avviamento o fermata). | |
| Non Applicabile Durante la giornata l'impianto controllato ha superato lo stato di minimo tecnico per una durata inferiore alla mimima richiesta, quindi il valore medio calcolato non è significativo (ex D.Lgs. 152/06). L'impianto controllato, per quanto concerna la media aggregata, è da considerare fermo | |
| Non Disponibile Le informazioni per la grandezza non sono disponibili a causa di problemi tecnici del sistema di misurazione o memorizzazione. | |
| Fuori Scansione Le informazioni non sono state effettuate a causa di guasto o manutenzione delle apparecchiature di misurazione. | |
| Superamento soglia normativa Il valore medio misurato è superiore al valore massimo ammissibile. |
Italcementi - Matera - 752-0100-00