Italcementi - Matera
Emissioni Forno
Analisi Valori Medi
| Polveri | ||
| Ossidi di zolfo [SO2] | ||
| Ossidi di azoto [NOx come NO2] | ||
| Ossido di carbonio [CO] | ||
| Acido cloridrico [HCl] | ||
| Carbonio Organico totale [TOC] | ||
| Ammoniaca [NH3] |
[Mese Precedente] [Mese Successivo] [Anno 2022] [Principale]
| |
Polveri @ 10%O2 - convalidato mg/Nm³ |
SO2 @ 10%O2 - convalidato mg/Nm³ |
NOx @ 10%O2 - convalidato mg/Nm³ |
CO @ 10%O2 - convalidato mg/Nm³ |
HCl @ 10%O2 - convalidato mg/Nm³ |
TOC @ 10%O2 - convalidato mg/Nm³ |
NH3 @ 10%O2 - convalidato mg/Nm³ |
| 01/11/2022 | 0.2 | 3.6 | 396.2 | 328.3 | 0.7 | 15.5 | 1.3 |
| 02/11/2022 | 0.2 | 3.2 | 393.7 | 419.8 | 0.2 | 17.0 | 5.2 |
| 03/11/2022 | 0.2 | 2.5 | 375.9 | 441.3 | 0.2 | 16.6 | 2.7 |
| 04/11/2022 | 0.2 | 3.1 | 375.2 | 402.0 | 0.2 | 17.5 | 2.0 |
| 05/11/2022 | 0.2 | 3.0 | 385.7 | 335.8 | 0.2 | 16.3 | 1.4 |
| 06/11/2022 | 0.2 | 10.6 | 255.6 | 369.2 | 1.1 | 14.7 | 6.1 |
| 07/11/2022 | 0.2 | 3.8 | 199.3 | 526.1 | 0.2 | 15.6 | 1.3 |
| 08/11/2022 | 0.2 | 4.0 | 379.8 | 303.5 | 1.2 | 14.1 | 1.5 |
| 09/11/2022 | 0.2 | 6.5 | 396.3 | 273.2 | 0.2 | 14.7 | 3.0 |
| 10/11/2022 | 0.2 | 5.0 | 362.4 | 382.5 | 0.2 | 14.4 | 2.4 |
| 11/11/2022 | 0.2 | 2.7 | 376.6 | 375.1 | 0.2 | 14.3 | 1.4 |
| 12/11/2022 | 0.2 | 2.5 | 369.8 | 329.0 | 0.2 | 14.6 | 0.6 |
| 13/11/2022 | 0.2 | 8.3 | 391.3 | 351.6 | 0.2 | 15.9 | 2.0 |
| 14/11/2022 | 0.2 * | 7.9 * | 395.1 * | 356.1 * | 0.2 * | 16.1 * | 0.7 * |
| 15/11/2022 | 0.2 | 2.5 | 337.2 | 291.9 | 1.0 | 14.1 | 1.4 |
| 16/11/2022 | 0.2 | 2.5 | 375.2 | 221.6 | 0.3 | 14.5 | 1.3 |
| 17/11/2022 | 0.2 | 6.1 | 324.4 | 418.3 | 0.6 | 15.3 | 5.3 |
| 18/11/2022 | 0.2 | 3.2 | 364.2 | 357.9 | 0.2 | 14.3 | 2.0 |
| 19/11/2022 | 0.2 | 2.7 | 376.3 | 443.9 | 0.2 | 14.0 | 0.8 |
| 20/11/2022 | 0.2 | 5.8 | 393.1 | 373.1 | 0.3 | 15.0 | 1.7 |
| 21/11/2022 | 0.2 | 2.8 | 386.0 | 380.9 | 0.2 | 12.5 | 1.1 |
| 22/11/2022 | 0.2 | 7.0 | 388.0 | 430.8 | 0.3 | 16.4 | 4.4 |
| 23/11/2022 | 0.2 | 7.8 | 380.5 | 327.6 | 1.1 | 14.7 | 8.6 |
| 24/11/2022 | 0.2 | 2.5 | 395.7 | 346.0 | 0.2 | 11.7 | 0.2 |
| 25/11/2022 | 0.2 | 2.5 | 390.5 | 407.2 | 0.2 | 13.3 | 0.3 |
| 26/11/2022 | 0.2 | 3.2 | 376.1 | 427.6 | 0.4 | 13.6 | 6.4 |
| 27/11/2022 | 0.2 | 3.1 | 383.2 | 363.0 | 0.3 | 13.3 | 2.7 |
| 28/11/2022 | 0.2 | 2.5 | 306.3 | 281.2 | 0.2 | 13.1 | 1.2 |
| 29/11/2022 | 0.2 | 2.6 | 348.3 | 199.6 | 0.2 | 12.7 | 1.1 |
| 30/11/2022 | 0.2 | 2.5 | 353.2 | 472.6 | 0.2 | 12.8 | 0.8 |
| Soglia | 10.0 | 50.0 | 450.0 | 600.0 | 10.0 | 30.0 | 30.0 |
| Nr Sup. | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Max | 0.2 | 10.6 | 396.3 | 526.1 | 1.2 | 17.5 | 8.6 |
| Min | 0.2 | 2.5 | 199.3 | 199.6 | 0.2 | 11.7 | 0.2 |
| |
Polveri @ 10%O2 - convalidato mg/Nm³ |
SO2 @ 10%O2 - convalidato mg/Nm³ |
NOx @ 10%O2 - convalidato mg/Nm³ |
CO @ 10%O2 - convalidato mg/Nm³ |
HCl @ 10%O2 - convalidato mg/Nm³ |
TOC @ 10%O2 - convalidato mg/Nm³ |
NH3 @ 10%O2 - convalidato mg/Nm³ |
| Mese | 0.2 | 4.0 | 370.6 | 366.7 | 0.3 | 14.6 | 2.3 |
| SemiOre valide | 1216 | 1221 | 1221 | 1221 | 1221 | 1221 | 1221 |
| SemiOre N.F. | 1294 | 1294 | 1294 | 1294 | 1294 | 1294 | 1294 |
[Mese Precedente] [Mese Successivo] [Anno 2022] [Principale]
| Non Valido - Le misurazioni non sono significative in quanto durante il periodo le apparecchiature od il sistema di misurazione ha dichiarato malfunzionamenti, quindi le misurazioni effettuate non sono attendibili. - Lo stato dell'impianto controllato è relativo a momenti di esercizio transitorio (avviamento o fermata). | |
| Non Applicabile Durante la giornata l'impianto controllato ha superato lo stato di minimo tecnico per una durata inferiore alla mimima richiesta, quindi il valore medio calcolato non è significativo (ex D.Lgs. 152/06). L'impianto controllato, per quanto concerna la media aggregata, è da considerare fermo | |
| Non Disponibile Le informazioni per la grandezza non sono disponibili a causa di problemi tecnici del sistema di misurazione o memorizzazione. | |
| Fuori Scansione Le informazioni non sono state effettuate a causa di guasto o manutenzione delle apparecchiature di misurazione. | |
| Superamento soglia normativa Il valore medio misurato è superiore al valore massimo ammissibile. |
Italcementi - Matera - 752-0100-00