Heidelberg Materials - Matera 
Emissioni Forno 
Analisi Valori Medi 

LIMITI DI EMISSIONE (dal 01/01/2018)

Polveri
10
[mg/Nm3]
Ossidi di zolfo [SO2]
50
[mg/Nm3]
Ossidi di azoto [NOx come NO2]
450
[mg/Nm3]
Ossido di carbonio [CO]
600
[mg/Nm3]
Acido cloridrico [HCl]
10
[mg/Nm3]
Carbonio Organico totale [TOC]
30
[mg/Nm3 come C]
Ammoniaca [NH3]
30
[mg/Nm3]

  [Mese Precedente]    [Mese Successivo]    [Anno 2024]    [Principale]

 

Mensile lineare 01/2024
 
 
Polveri @ 10%O2 
- convalidato 
 
mg/Nm³
 
SO2 @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NOx @ 10%O2 - 
convalidato 
 
mg/Nm³
 
CO @ 10%O2 - convalidato 
 
 
mg/Nm³
 
HCl @ 10%O2 - 
convalidato 
 
mg/Nm³
 
TOC @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NH3 @ 10%O2 - 
convalidato 
 
mg/Nm³
01/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
02/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
03/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
04/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
05/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
06/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
07/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
08/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
09/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
10/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
11/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
12/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
13/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
14/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
15/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
16/01/2024    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
17/01/2024 0.1 * 3.7 * 378.8 * 264.0 * 3.1 * 16.4 * 3.2 *
18/01/2024 0.2 4.2 388.1 452.2 0.8 18.3 3.6
19/01/2024 0.2 5.5 399.0 398.1 0.9 16.5 9.0
20/01/2024 0.2 4.5 399.3 449.3 0.3 16.8 4.5
21/01/2024 0.2 4.9 397.0 442.9 0.4 17.1 4.5
22/01/2024 0.2 6.8 397.7 402.5 0.8 16.0 6.3
23/01/2024 0.2 4.1 398.0 441.0 0.3 15.1 3.5
24/01/2024 0.2 5.1 409.6 365.7 1.3 15.2 4.5
25/01/2024 0.3 5.1 409.2 437.3 0.3 16.3 3.2
26/01/2024 0.3 7.5 384.4 304.0 0.7 14.9 4.3
27/01/2024 0.3 * 6.2 * 397.2 * 317.2 * 0.4 * 14.2 * 6.4 *
28/01/2024 0.3 3.8 392.3 381.8 0.4 15.0 3.7
29/01/2024 0.3 4.3 384.3 335.7 0.3 12.4 4.2
30/01/2024 0.3 3.8 388.3 380.0 0.7 8.6 5.0
31/01/2024 0.3 3.7 391.1 415.9 0.3 10.0 3.3
  
Soglia 10.0 50.0 450.0 600.0 10.0 30.0 30.0
Nr Sup. 0 0 0 0 0 0 0
Max 0.3 7.5 409.6 452.2 1.3 18.3 9.0
Min 0.2 3.7 384.3 304.0 0.3 8.6 3.2
  
 
  
 
Polveri @ 10%O2 
- convalidato 
 
mg/Nm³
 
SO2 @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NOx @ 10%O2 - 
convalidato 
 
mg/Nm³
 
CO @ 10%O2 - convalidato 
 
 
mg/Nm³
 
HCl @ 10%O2 - 
convalidato 
 
mg/Nm³
 
TOC @ 10%O2 - 
convalidato 
 
mg/Nm³
 
NH3 @ 10%O2 - 
convalidato 
 
mg/Nm³
Mese 0.2 4.8 395.2 396.5 0.6 14.8 4.7
SemiOre valide 629 629 629 629 629 629 629
SemiOre N.F. 669 669 669 669 669 669 669
  

  [Mese Precedente]    [Mese Successivo]    [Anno 2024]    [Principale]


Legenda MESE

*
Non Valido
- Le misurazioni non sono significative in quanto durante il periodo le apparecchiature od il sistema di misurazione ha dichiarato malfunzionamenti, quindi le misurazioni effettuate non sono attendibili.
- Lo stato dell'impianto controllato è relativo a momenti di esercizio transitorio (avviamento o fermata).
N.A.
Non Applicabile
Durante la giornata l'impianto controllato ha superato lo stato di minimo tecnico per una durata inferiore alla mimima richiesta, quindi il valore medio calcolato non è significativo (ex DM 21/12/1995). L'impianto controllato, per quanto concerna la media aggregata, è da considerare fermo
N.D.
Non Disponibile
Le informazioni per la grandezza non sono disponibili a causa di problemi tecnici del sistema di misurazione o memorizzazione.
F.S.
Fuori Scansione
Le informazioni non sono state effettuate a causa di guasto o manutenzione delle apparecchiature di misurazione.
>
Superamento soglia normativa
Il valore medio misurato è superiore al valore massimo ammissibile.

 

 

HM - Matera - 752-0100-00 

PF Sistemi s.r.l. Milano